@@ -45,7 +45,7 @@ Internally registered signals shall be replicated. Protection against transients
\end{enumerate}
\subsection{PMU\_counters}
\begin{enumerate}
\item\underline{Fail mode:}\textit{Softrst\_i} transient errors can occur. The unit shall handle error detection internally. One error can reset all counters. \textbf{Priority High}.\\
\item\underline{Fail mode:}\textit{Softrst\_i} transient errors can occur. The unit shall handle error detection internally. One error can reset all counters. \textbf{Priority Medium}.\\
\underline{Corrective action:} Provide redundant signals from the source of Softrst\_i and do error detection within the module.\\
\\
\item\underline{Fail mode:}\textit{en\_i} transient errors can occur. The unit shall handle error detection internally. One error can disable the counters for a single cycle. \textbf{Priority low}.\\